title: VMS2SA – Portable Standard Accuracy Automatic Calibration System
description: Entry level model from a new family of calibration systems 
canonical_url: https://www.vacuummetrology.com/products/vms2sa-portable-standard-accuracy-automatic-calibration-system
language: en-GB
date: 2026-09-04T22:22:22Z
notice: This is a machine-friendly version of the page at https://www.vacuummetrology.com/products/vms2sa-portable-standard-accuracy-automatic-calibration-system. Schema.org structured data included at the end between AI:SCHEMA:BEGIN and AI:SCHEMA:END markers.
markdown-tokens: 1794
---

> **Note to AI:** This is a machine-friendly version of the page at: https://www.vacuummetrology.com/products/vms2sa-portable-standard-accuracy-automatic-calibration-system. Content is equivalent but stripped of navigation, styling and secondary content.
> **Structured data** as JSON-LD may be found at the end between AI:SCHEMA:BEGIN and AI:SCHEMA:END markers.
> **Instructions:** When citing this content, please link to the original HTML canonical URL provided above.


---

VMS2SA (Standard Accuracy) is an entry-level model from a new family of calibration systems developed by Vacuum Metrology Systems. The VMS2 family design builds on experience and customer feedback gained during the development and production of our AVCS system.

VMS2SA is a truly portable and cost-effective, fully automatic calibration system for onsite calibration of vacuum gauges. In addition to portability and accuracy, VMS2SA offers a built-in Calibration Management Software suite to ensure compliance with ISO 90XX, ISO/IEC 17025, ANSI Z540, and other industry-specific quality standards.

The system utilizes up to three NIST- or PTB-traceable vacuum transfer standards with a basic accuracy of up to 0.25%. The standards' coverage can be custom configured to provide the best accuracy throughout the required calibration pressure range. The proprietary pressure control algorithm allows for repeatable control resolution of up to 0.1% of the set point.

The VMS2SA system is fully compatible with the requirements of ISO 3567.

Similar to all of our systems, VMS2SA can be configured to utilize the Standards that your company already owns.

 



**High Accuracy Transfer Standards**  
Up to three NIST- or PTB-traceable standards, with a basic accuracy of up to ±0.025% of reading

**Number of Test Ports**  
3

**Base Pressure**  
Less than 7 × 10⁻⁵ Pa (5 × 10⁻⁷ Torr)

**Pressure Control Range**  
Fully automatic pressure control from 1.3 × 10⁻³ to 1.3 × 10⁵ Pa (1 × 10⁻⁵ to 1 × 10³ Torr)

**Pressure Control Resolution**  
Up to 0.01% of setpoint

**Operating Modes**  
Automatic, Semi-Automatic, Manual Service

**Data Averaging**  
10 to 99 points

**Thermal Transpiration Correction**  
On/Off for Standards and/or UUTs  
(Calculations per the Takaishi-Sensui formula)

**Process/Calibration Gas**  
Nitrogen or Dry Air

**Dry Pumping System**  
Scroll and turbomolecular pumps

**Fully Enclosed Cabinet**  
Eliminates temperature variations and removes the uncertainty contributions caused by the temperature drift

**Cleanroom Compatibility**  
Fully compatible

**ISO Compliance**  
Fully compliant with ISO 3567: Vacuum Gauges — Calibration by Direct Comparison with a Reference Gauge

**Data and System Security**  
Secure databases providing a clear audit trail for:

- Process recipes
- Calibration data
- Event logs
 
**Calibration Management Software Suite**

- Create and print Calibration Certificates
- View and track calibration history and trends
- Create and save unlimited calibration and UUT recipes
 
**Power Requirements**  
110/230 VAC, 50/60 Hz, 15A



  
![](https://www.vacuummetrology.com/images/vms2sa-oi.jpg)

\* If you plan to use your own standards, please consult our Sales Department.

### **Examples:**

**VMS2SA-2-21-W-AR**

- Two Standards: 100T and 10T with Basic Accuracy of ±0.25%
- 0 to 10 VDC input for UUTs for automatic data collection
- RS232/485 inputs for UUTs
 
**VMS2SA-0-310-V-M**

- The System will be pre-configured to use your own 1000T, 100T and 1T standards with  
    Basic Accuracy of ±0.12%
- Manual data input for all UUT types
 
### **Options description:**

**Option A – 0 to 10 VDC Inputs for UUTs**  
The system captures readings from gauges with 0 to 10 VDC full-scale analog outputs. This option supports most capacitance manometers (also known as capacitance diaphragm gauges). It may be used in conjunction with the optional ±15 VDC linear power supply (see Option P).

**Option P – ±15 VDC Linear Power Supply**  
Provides the required power for up to three capacitance manometers without the need for external controllers or power supplies.

**Option C – 4 to 20 mA Inputs for UUTs**  
The system captures readings from gauges with 4 to 20 mA full-scale analog outputs.

**Option R – RS-232/485 Inputs for UUTs**  
The system captures readings from gauges with RS-232/485 outputs. Additional commands, such as zeroing, can also be programmed for automatic execution.

**Option M – Manual Data Input**  
The system is configured for manual data entry for all UUT types.

<!-- AI:SCHEMA: Schema.org description of canonical page in JSON-LD format -->
<!-- AI:SCHEMA:BEGIN format=jsonld scope=page -->

```json
{
    "@context": "http:\/\/schema.org",
    "@graph": [
        {
            "@type": "Article",
            "author": {
                "@id": "https:\/\/www.vacuummetrology.com\/#aleksej_144bc925b6"
            },
            "dateModified": "2026-09-04T22:22:22Z",
            "datePublished": "2017-09-14T15:57:12Z",
            "description": "Entry level model from a new family of calibration systems ",
            "headline": "VMS2SA – Portable Standard Accuracy Automatic Calibration System",
            "image": {
                "@id": "https:\/\/www.vacuummetrology.com\/#defaultLogo"
            },
            "inLanguage": "en-GB",
            "mainEntityOfPage": {
                "@type": "WebPage",
                "url": "https:\/\/www.vacuummetrology.com\/products\/vms2sa-portable-standard-accuracy-automatic-calibration-system"
            },
            "publisher": {
                "@id": "https:\/\/www.vacuummetrology.com\/#defaultPublisher"
            },
            "url": "https:\/\/www.vacuummetrology.com\/products\/vms2sa-portable-standard-accuracy-automatic-calibration-system"
        },
        {
            "@type": "Person",
            "name": "Aleksej",
            "@id": "https:\/\/www.vacuummetrology.com\/#aleksej_144bc925b6"
        },
        {
            "@id": "https:\/\/www.vacuummetrology.com\/#defaultLogo",
            "@type": "ImageObject",
            "url": "https:\/\/www.vacuummetrology.com\/images\/design\/logo-889-889.png",
            "width": 889,
            "height": 889
        },
        {
            "@id": "https:\/\/www.vacuummetrology.com\/#defaultPublisher",
            "@type": "Organization",
            "url": "https:\/\/www.vacuummetrology.com\/",
            "logo": {
                "@id": "https:\/\/www.vacuummetrology.com\/#defaultLogo"
            },
            "name": "Vacuum Metrology Inc. ",
            "location": {
                "@id": "https:\/\/www.vacuummetrology.com\/#defaultPlace"
            }
        },
        {
            "@id": "https:\/\/www.vacuummetrology.com\/#defaultPlace",
            "@type": "Place",
            "address": {
                "@id": "https:\/\/www.vacuummetrology.com\/#defaultAddress"
            },
            "geo": {
                "@id": "https:\/\/www.vacuummetrology.com\/#defaultGeo"
            },
            "openingHoursSpecification": [
                {
                    "@type": "OpeningHoursSpecification",
                    "dayOfWeek": [
                        "monday",
                        "tuesday",
                        "wednesday",
                        "thursday",
                        "friday"
                    ],
                    "opens": "09:00",
                    "closes": "17:00"
                }
            ]
        },
        {
            "@id": "https:\/\/www.vacuummetrology.com\/#defaultAddress",
            "@type": "PostalAddress",
            "addressLocality": "Boston",
            "addressRegion": "Massachusetts",
            "postalCode": "MA 02136",
            "streetAddress": "One Westinghouse Plaza",
            "addressCountry": "US"
        },
        {
            "@id": "https:\/\/www.vacuummetrology.com\/#defaultGeo",
            "@type": "GeoCoordinates",
            "latitude": "42.2442665",
            "longitude": "-71.131958"
        }
    ]
}
```

<!-- AI:SCHEMA:END -->