title: AVCS3SD – Stationary Automatic Calibration System
description: fast precision automatic, semiautomatic or manual calibration and verification of various vacuum gauges 
canonical_url: https://www.vacuummetrology.com/products/avcs-3sd
language: en-GB
date: 2026-09-04T22:09:29Z
notice: This is a machine-friendly version of the page at https://www.vacuummetrology.com/products/avcs-3sd. Schema.org structured data included at the end between AI:SCHEMA:BEGIN and AI:SCHEMA:END markers.
markdown-tokens: 1955
---

> **Note to AI:** This is a machine-friendly version of the page at: https://www.vacuummetrology.com/products/avcs-3sd. Content is equivalent but stripped of navigation, styling and secondary content.
> **Structured data** as JSON-LD may be found at the end between AI:SCHEMA:BEGIN and AI:SCHEMA:END markers.
> **Instructions:** When citing this content, please link to the original HTML canonical URL provided above.


   #  AVCS3SD – Stationary Automatic Calibration System 

  The AVCS3SD Automated Vacuum Calibration System is designed for fast, precision automatic, semiautomatic, or manual calibration and verification of various vacuum gauges at pressures from 1.3×10⁻³ to 1.3×10⁵ Pa (1×10⁻⁵ to 1000 Torr). The system provides calibration capabilities for Capacitance Manometers, Pirani, Piezo, Cold Cathode (Penning), Hot Cathode (Bayard-Alpert), and other types of gauges.

The system is compliant with the requirements of the ISO 3567:2011(E) standard, “Vacuum gauges – Calibration by direct comparison with a reference gauge.”

The system incorporates three high-accuracy NIST- or PTB-traceable transfer standards with an accuracy of up to ±0.025% (±zero and span), temperature regulated at 45°C; and a fully automatic, patent-pending pressure and process control system, along with a Calibration Management Software.

The stainless steel vacuum chamber incorporates 3 ports for the Transfer Standards and 3 Test Ports equipped with KF16-style flanges. All test and transfer standard ports incorporate automatic failsafe isolation valves. The two-stage pumping system consists of a dry (scroll) backing pump and a turbomolecular pump.

The system is built on a cleanroom-compatible aluminum frame with all of the components mounted within the frame footprint. The frame has built-in casters and leveling pads.

AVCS automation consists of a PC running the GUI and process control and an Allen-Bradley PLC responsible for the operation of the vacuum hardware and pressure control loop.

AVCS offers a built-in Calibration Management Software suite to ensure compliance with ISO 90XX, ISO/IEC 17025, ANSI Z540, and other industry-specific quality standards.

  **High Accuracy Transfer Standards**  
Up to three NIST- or PTB-traceable standards, with a basic accuracy of up to ±0.025% of reading

**Number of Test Ports**  
3

**Base Pressure**  
Less than 7 × 10⁻⁵ Pa (5 × 10⁻⁷ Torr)

**Pressure Control Range**  
Fully automatic pressure control from 1.3 × 10⁻³ to 1.3 × 10⁵ Pa (1 × 10⁻⁵ to 1 × 10³ Torr)

**Pressure Control Resolution**  
Up to 0.01% of setpoint

**Operating Modes**  
Automatic, Semi-Automatic, Manual Service

**Data Averaging**  
10 to 99 points

**Thermal Transpiration Correction**  
On/Off for Standards and/or UUTs  
(Calculations per the Takaishi-Sensui formula)

**Process/Calibration Gas**  
Nitrogen or Dry Air

**Dry Pumping System**  
Scroll and turbomolecular pumps

**Fully Enclosed Cabinet**  
Eliminates temperature variations and reduces uncertainty contributions caused by temperature drift

**Cleanroom Compatibility**  
Fully compatible

**ISO Compliance**  
Fully compliant with ISO 3567: Vacuum Gauges — Calibration by Direct Comparison with a Reference Gauge

**Data and System Security**  
Secure databases providing a clear audit trail for:

- Process recipes
- Calibration data
- Event logs
 
**Calibration Management Software Suite**

- Create and print Calibration Certificates
- View and track calibration history and trends
- Create and save unlimited calibration and UUT recipes
 
**Power Requirements**  
110/230 VAC, 50/60 Hz, 15A

    
![AVCS3SD Dimensions](https://www.vacuummetrology.com/images/avcs3sd-dimension.jpg)

  ### **AVCS3SD Product Brochure** 

[ ![](https://www.vacuummetrology.com/images/icons/pdf-big.jpg)  
Download size 520 Kb](https://www.vacuummetrology.com/images/brochures/AVCS3SD.pdf)

  ![](https://www.vacuummetrology.com/images/AVCS-oi.jpg)

\* If you plan to use your own standards, please consult our Sales Department.

### **Examples:**

**AVCS3SD-210-Y-AP**

- Three standards: 100 Torr, 10 Torr, and 1 Torr, with a basic accuracy of ±0.05%
- 0 to 10 VDC input for UUTs for automatic data collection
- ±15 VDC linear power supply for UUTs
 
**AVCS0SD-320-X-M**

- The System will be pre-configured to use your own 1000T, 100T, 1T standards with Basic  
    Accuracy of ±0.08%.
- Manual data input for all UUT types
 
### **Options description:**

**Option A – 0 to 10 VDC Inputs for UUTs**  
The system captures readings from gauges with 0 to 10 VDC full-scale analog outputs. This option supports most capacitance manometers (also known as capacitance diaphragm gauges). It may be used in conjunction with the optional ±15 VDC linear power supply (see Option P).

**Option P – ±15 VDC Linear Power Supply**  
Provides the required power for up to three capacitance manometers without the need for external controllers or power supplies.

**Option C – 4 to 20 mA Inputs for UUTs**  
The system captures readings from gauges with 4 to 20 mA full-scale analog outputs.

**Option R – RS-232/485 Inputs for UUTs**  
The system captures readings from gauges with RS-232/485 outputs. Additional commands, such as zeroing, can also be programmed for automatic execution.

**Option M – Manual Data Input**  
The system is configured for manual data entry for all UUT types.

<!-- AI:SCHEMA: Schema.org description of canonical page in JSON-LD format -->
<!-- AI:SCHEMA:BEGIN format=jsonld scope=page -->

```json
{
    "@context": "http:\/\/schema.org",
    "@graph": [
        {
            "@type": "Article",
            "author": {
                "@id": "https:\/\/www.vacuummetrology.com\/#aleksej_144bc925b6"
            },
            "dateModified": "2026-09-04T22:09:29Z",
            "datePublished": "2016-02-19T07:40:03Z",
            "description": "fast precision automatic, semiautomatic or manual calibration and verification of various vacuum gauges ",
            "headline": "AVCS3SD – Stationary Automatic Calibration System",
            "image": {
                "@id": "https:\/\/www.vacuummetrology.com\/#defaultLogo"
            },
            "inLanguage": "en-GB",
            "mainEntityOfPage": {
                "@type": "WebPage",
                "url": "https:\/\/www.vacuummetrology.com\/products\/avcs-3sd"
            },
            "publisher": {
                "@id": "https:\/\/www.vacuummetrology.com\/#defaultPublisher"
            },
            "url": "https:\/\/www.vacuummetrology.com\/products\/avcs-3sd"
        },
        {
            "@type": "Person",
            "name": "Aleksej",
            "@id": "https:\/\/www.vacuummetrology.com\/#aleksej_144bc925b6"
        },
        {
            "@id": "https:\/\/www.vacuummetrology.com\/#defaultLogo",
            "@type": "ImageObject",
            "url": "https:\/\/www.vacuummetrology.com\/images\/design\/logo-889-889.png",
            "width": 889,
            "height": 889
        },
        {
            "@id": "https:\/\/www.vacuummetrology.com\/#defaultPublisher",
            "@type": "Organization",
            "url": "https:\/\/www.vacuummetrology.com\/",
            "logo": {
                "@id": "https:\/\/www.vacuummetrology.com\/#defaultLogo"
            },
            "name": "Vacuum Metrology Inc. ",
            "location": {
                "@id": "https:\/\/www.vacuummetrology.com\/#defaultPlace"
            }
        },
        {
            "@id": "https:\/\/www.vacuummetrology.com\/#defaultPlace",
            "@type": "Place",
            "address": {
                "@id": "https:\/\/www.vacuummetrology.com\/#defaultAddress"
            },
            "geo": {
                "@id": "https:\/\/www.vacuummetrology.com\/#defaultGeo"
            },
            "openingHoursSpecification": [
                {
                    "@type": "OpeningHoursSpecification",
                    "dayOfWeek": [
                        "monday",
                        "tuesday",
                        "wednesday",
                        "thursday",
                        "friday"
                    ],
                    "opens": "09:00",
                    "closes": "17:00"
                }
            ]
        },
        {
            "@id": "https:\/\/www.vacuummetrology.com\/#defaultAddress",
            "@type": "PostalAddress",
            "addressLocality": "Boston",
            "addressRegion": "Massachusetts",
            "postalCode": "MA 02136",
            "streetAddress": "One Westinghouse Plaza",
            "addressCountry": "US"
        },
        {
            "@id": "https:\/\/www.vacuummetrology.com\/#defaultGeo",
            "@type": "GeoCoordinates",
            "latitude": "42.2442665",
            "longitude": "-71.131958"
        }
    ]
}
```

<!-- AI:SCHEMA:END -->